
At FPC Global, our people are our greatest asset. We’re a fast-growing, global consultancy where collaboration, innovation, and ambition come together to deliver exceptional outcomes across the full facility lifecycle.
Founded in 2014 by our CEO, Dean Francis, we’ve grown into a team of 140+ professionals working across the Americas, EMEA, APAC, and our London headquarters. We partner with clients to deliver integrated, future-focused consultancy services—setting new benchmarks for sustainability, technology, and performance.
We believe great ideas can come from anywhere. That’s why we foster a culture where voices are heard, initiative is encouraged, and careers are built with purpose.
FPC Global is seeking a Senior BMS Commissioning Engineer (CxA) to provide independent technical oversight, validation, and acceptance of Building Management Systems (BMS) and associated ELV and environmental risk monitoring systems across Tier III / Tier IV data centre developments
Acting on behalf of the owner/operator, the role ensures that control systems, monitoring platforms, and automated responses accurately reflect design intent, support operational playbooks, and demonstrate fault tolerance through Integrated Systems Testing (IST)
This is a site-focused, assurance-led role requiring deep technical expertise in controls, systems integration, and mission-critical operations.
Key Responsibilities
Client-Side BMS Commissioning Authority
Act as Commissioning Authority (CxA) for BMS and integrated monitoring systems, representing the owner’s technical and operational interests.
Define, review and enforce BMS commissioning strategies, acceptance criteria and readiness milestones
Integrated Systems Testing (IST) Assurance
Review, challenge and approve BMS-led IST methodologies and scripts in accordance with Uptime Institute Tier Standards
Witness and validate failure mode, redundancy and fault-tolerance testing, ensuring automated responses meet availability objectives.
Confirm BMS supports operator situational awareness during degraded and fault conditions.
Mechanical & Electrical Integration Validation
Independently validate BMS integration with:
Mechanical systems (chillers, CRAH/CRAC, AHUs, pumps, valves, heat rejection plant)
Electrical systems via EPMS (UPS, generators, switchgear, PDUs, STS)
Verify sequences of operation, interlocks, alarms, trending and control logic accuracy.
ELV Systems Acceptance (Client Representation)
Own client-side acceptance of ELV systems, including:
Access control and security monitoring
CCTV and video management interfaces
Fire alarm monitoring and supervisory interfaces (where permitted)
Network resilience and segregation supporting BMS / ELV platforms
Ensure ELV systems are fully integrated, documented and operationally visible.
Leak Detection Systems Assurance
Validate commissioning and integration of water leak detection (WLD) systems across white space, plant areas and critical pathways.
Confirm zoning, alarm prioritisation, escalation logic and operator response workflows.
Witness leak-related IST scenarios and approve system acceptance.
Rodent Detection & Environmental Risk Monitoring
Act as client authority for rodent detection and environmental risk monitoring systems
Validate sensor coverage, alarm logic, escalation paths and BMS integration.
Ensure alignment with hyperscale environmental risk mitigation strategies.
Design & Commissionability Reviews
Perform independent design reviews of BMS, controls, and ELV architectures at all project stages.
Review control philosophies, points lists, network topologies, graphics standards and vendor submittals for operability and resilience.
Vendor & Contractor Oversight
Provide technical oversight of BMS, controls and ELV vendors without direct installation responsibility.
Identify non-conformances, issue technical observations and drive corrective actions to closure prior to acceptance.
Documentation, Acceptance & Handover
Review and approve commissioning documentation including:
Commissioning plans, test procedures, and IST scripts
Point-to-point and functional test evidence
Configuration baselines and as-built records
Final commissioning and acceptance reports
Support operator training, handover and transition to steady-state operations.
Compliance & Readiness Assurance
Ensure alignment with:
Uptime Institute Tier Standards (TCCF focus)
ASHRAE, IEC, ISO and applicable local codes
Client-specific hyperscale standards and operational playbooks
Confirm closure of all critical items prior to RFS / RFO milestones
Qualifications & Experience
Essential Qualifications
Degree in Engineering (Mechanical, Electrical, Controls, or equivalent).
8–12+ years experience in BMS / controls commissioning.
Minimum 5 years in a client-side, CxA, or independent assurance role within data centres or mission-critical facilities.
Technical Expertise
Advanced knowledge of:
Data centre BMS architectures and hyperscale operating models
Integrated mechanical, electrical, and ELV monitoring environments
Failure mode testing, IST execution and operational readiness validation
Control system resilience, redundancy and cybersecurity considerations
Documentation & Reporting
Authoring and review of commissioning strategies, acceptance criteria and test scripts.
Evaluation of cause-and-effect matrices and control philosophies.
Production of formal CxA reports, issue logs and acceptance recommendations.
Tools & Platforms
Enterprise BMS platforms (Schneider, Siemens, Honeywell, Johnson Controls).
EPMS and supervisory monitoring systems.
AutoCAD / BIM / Visio.
Direct experience supporting Uptime Tier Certification of Constructed Facility (TCCF)
Experience with FDD and automated commissioning systems is highly advantageous.
Why Join FPC?
At FPC, we’re not just a company—we’re a thriving community where innovation flourishes, ideas are celebrated, and careers are shaped. When you join us, you become part of a dynamic team that:
Together, we’ll build tomorrow’s digital planet—and you’ll be part of something truly extraordinary.

Founded in 2014, Facility Performance Consulting (FPC) set out on a mission to "Build Tomorrow’s Digital Planet" by delivering highly specialised, facility life-cycle integrated consulting services for the Built Environment.
By 2025, FPC Group has grown into a global leader in innovative business solutions and project execution, with over 150 experts across the UK, Ireland, the US & Americas, Europe, India, and APAC. Our business operates under two key pillars:
FPC Global ~
We deliver Technical Consultancy & Advisory Services in Technical Program & Project Management, Building Performance Services, Building Sustainability & Energy Efficiency, Cyber Security.
FPC Digital ~
We deliver Digital Building Services and Frictionless Building Design including Digital Building Design, Engineering and Operations.
Our Global Reach:
Headquartered in Rugby, Warwickshire, UK, FPC Global operates a network of regional offices to support clients worldwide:
EMEA – London, UK & Dublin
US & Americas – San Francisco
India – Bangalore
APAC – Singapore
As we continue to expand, FPC remains dedicated to supporting our diverse client base worldwide
Join Us:
Explore current opportunities → www.fpc-global.com/hiring