
Please click here to apply through our internal career site Find Jobs - Elekta.
Elekta is shaping the standard of care, together with healthcare providers, by developing precision radiation medicine that brings advanced radiotherapy into routine clinical practice. Our solutions support consistent, efficient and personalized care, addressing evolving patient needs. Through adaptive radiotherapy, precision treatment delivery and integrated workflows, Elekta supports care teams across a range of clinical settings. Each year more than 2 million patients are treated using Elekta solutions across over 130 countries. Elekta is headquartered in Stockholm, Sweden, with over 4,000 employees and offices in more than 40 countries. The company is listed on Nasdaq Stockholm. For more information, visit elekta.com.
Cone-beam CT (CBCT) is an imaging technique widely used in radiation therapy for patient positioning and adaptive workflow. 2D projections are acquired from a cone-shaped X-ray beam rotating around the patient, and a 3D image is reconstructed from these projections. The imaging device is mounted directly on the treatment machine, i.e. a linear accelerator (linac), which allows for imaging the patient in the treatment position. However, the acquisition of CBCT images is relatively slow, and patient motion during the scan can lead to image artifacts and reduced image quality. Motion compensation techniques aim to mitigate these effects by estimating and correcting for patient motion during the reconstruction process. This thesis will investigate and prototype motion compensation methods for CBCT imaging in radiation therapy, with the goal of improving image quality and treatment accuracy.
Respiratory and cardiac motion are the dominant source of motion artifacts in CBCT for radio[1]therapy which cause blurring, streaking and banding artifacts in the reconstructed images (Chen et al., 2004). Currently deployed techniques to mitigate motion artifacts in CBCT include:
Each of the above techniques has its own limitations and/or disadvantages, and there is a need for more efficient methods. Recent research has explored advanced algorithms, such as deformable image registration and machine learning-based approaches (Amirian et al., 2024), to improve motion estimation in medical imaging. This thesis will build upon these advancements to develop a novel motion compensation algorithm that can be integrated into our CBCT reconstruction pipeline.
The purpose of this thesis is to investigate and prototype motion compensation methods for CBCT imaging in radiation therapy. The aim is to develop a motion compensation algorithm that can effectively mitigate the effects of patient motion, particularly respiratory motion, while maintaining image quality, computational efficiency and minimizing the acquisition time and delivered dose to the patient. The thesis will involve a comprehensive literature review, algo[1]rithm development, and performance evaluation, with the goal of improving image quality and treatment accuracy in CBCT imaging for radiation therapy.
(a) Conduct a comprehensive literature review on existing motion compensation techniques in CBCT imaging.
(b) Develop, or adapt1, a motion compensation algorithm that can be integrated into the CBCT reconstruction pipeline.
(c) Evaluate the performance of the developed algorithm in terms of image quality, computational efficiency, and robustness.
(d) Compare the proposed algorithm with existing methods to assess its advantages and limitations.
(e) Document the methodology, results, and conclusions in a comprehensive report, and provide the source code for the developed algorithm.
The expected output of this thesis will be a prototype implementation of a motion compensation algorithm that can be integrated into our CBCT-image reconstruction pipeline. The student will be responsible for developing and testing the algorithm, as well as evaluating its performance in terms of image quality and computational efficiency. The final deliverables will include a comprehensive report detailing the methodology, results, and conclusions, as well as the source code for the developed algorithm.
The ideal candidate for this thesis project should have a strong background in physics, medical imaging, and machine learning. Preferred qualifications include experience with programming languages such as Python and familiarity with image processing libraries and frameworks. The student should be motivated, detail-oriented, and capable of working independently as well as collaboratively in a research environment. The project includes a literature study, algorithm development, and performance evaluation, so the student should be comfortable with both theoretical and practical aspects of research.
Amirian, M., Barco, D., Herzig, I., & Schilling, F.-P. (2024). Artifact reduction in 3D and 4D cone-beam computed tomography images with deep learning: A review. IEEE Access, 12, 10281–10295. https://doi.org/10.1109/ACCESS.2024.3353195
Chen, G. T., Kung, J. H., & Beaudette, K. P. (2004). Artifacts in computed tomography scan[1]ning of moving objects. Seminars in Radiation Oncology, 14 (1), 19–26. https://doi.org/https://doi.org/10.1053/j.semradonc.2003.10.004
Kincaid Jr., R. E., Yorke, E. D., Goodman, K. A., Rimner, A., Wu, A. J., & Mageras, G. S. (2013). Investigation of gated cone-beam CT to reduce respiratory motion blurring. Medical Physics, 40 (4), 041717. https://doi.org/https://doi.org/10.1118/1.4795336
Sonke, J.-J., Zijp, L., Remeijer, P., & van Herk, M. (2005). Respiratory correlated cone beam CT. Medical Physics, 32 (4), 1176–1186. https://doi.org/https://doi.org/10.1118/1.1869074

Each year, millions of people hear the words no one wants to hear: "You have cancer." And behind each diagnosis lies a unique story, a family that deserves hope, a future that's worth fighting for. We know that no two treatment journeys are the same and delivering care is far from simple. It's complex, urgent, and deeply human. That’s why we don’t back down from challenges—we rise to them. From the smallest tumor change to the toughest clinical decisions, we see every obstacle as an opportunity to progress. That is what drives us. The people undergoing treatment. The clinicians providing the care. We are united in purpose. Together, we can create a world where every patient has access to the highest standard of care. This is our commitment because for everyone, it's personal. We are leading the innovation in personalized radiation therapy solutions. We are Elekta.
Elekta reserves the right to remove any comment and to restrict access to its page at its sole discretion, without prior notice. The presence of user comments does not imply endorsement by Elekta, and Elekta makes no representations regarding the accuracy of such comments. User-generated content does not necessarily reflect the views, values, or positions of Elekta.