
Please click here to apply through our internal career site Find Jobs - Elekta.
Elekta is shaping the standard of care, together with healthcare providers, by developing precision radiation medicine that brings advanced radiotherapy into routine clinical practice. Our solutions support consistent, efficient and personalized care, addressing evolving patient needs. Through adaptive radiotherapy, precision treatment delivery and integrated workflows, Elekta supports care teams across a range of clinical settings. Each year more than 2 million patients are treated using Elekta solutions across over 130 countries. Elekta is headquartered in Stockholm, Sweden, with over 4,000 employees and offices in more than 40 countries. The company is listed on Nasdaq Stockholm. For more information, visit elekta.com.
Radiotherapy targets and surrounding anatomy can move during treatment. The Elekta Unity combines an MR scanner with a linear accelerator, enabling anatomy to be visualised during radiation delivery and allowing treatment adaptation based on real-time information. However, there are inherent latencies associated with image acquisition, image processing, data transfer, and motion estimation. To compensate for these latencies, future anatomical motion must be predicted. This project will investigate whether an AI-based approach can improve prediction accuracy at extended prediction horizons.
Radiotherapy treatments are designed with millimeter precision to ensure that high doses of radiation can be delivered to the target while sparing surrounding healthy tissues and critical anatomical structures. However, both the target and surrounding anatomy may move during treatment due to physiological processes such as respiration, peristalsis, and organ drift. The Elekta Unity can visualise and respond to this motion in real time, improving dosimetric accuracy and therefore improving patient outcomes.
The current Automatic Position Management (APM) framework acquires an orthogonal pair of 2D cine images at a rate of 5 Hz. Each image is compared with a reference image using rigid registration to estimate target motion. A prediction engine then extrapolates the observed motion to estimate the target position once all processing steps have been completed.
In the future, longer prediction horizons may be required to support more advanced image acquisition strategies, target-tracking approaches, or dose-based interventions. To enable these developments, a prediction algorithm must maintain accuracy while predicting further into the future. AI methods such as recurrent neural networks have shown promise for time-series prediction tasks both within and beyond radiation oncology and will therefore form the primary focus of this investigation.
The project will investigate the suitability of AI approaches for motion prediction on the Unity platform through the following objectives:
Who are we looking for?
We are looking for a master’s student in medical physics, computer science, applied mathematics, engineering physics, or a related scientific discipline.
Required profile:
Desirable experience:
Location: Elekta office, Stockholm
Supervisor: Ned Goodwin
Start date: Flexible

Each year, millions of people hear the words no one wants to hear: "You have cancer." And behind each diagnosis lies a unique story, a family that deserves hope, a future that's worth fighting for. We know that no two treatment journeys are the same and delivering care is far from simple. It's complex, urgent, and deeply human. That’s why we don’t back down from challenges—we rise to them. From the smallest tumor change to the toughest clinical decisions, we see every obstacle as an opportunity to progress. That is what drives us. The people undergoing treatment. The clinicians providing the care. We are united in purpose. Together, we can create a world where every patient has access to the highest standard of care. This is our commitment because for everyone, it's personal. We are leading the innovation in personalized radiation therapy solutions. We are Elekta.
Elekta reserves the right to remove any comment and to restrict access to its page at its sole discretion, without prior notice. The presence of user comments does not imply endorsement by Elekta, and Elekta makes no representations regarding the accuracy of such comments. User-generated content does not necessarily reflect the views, values, or positions of Elekta.