Design Engineer Ensure that the QMS confirms to ISO 9001:2015 Ensure processes are delivering intended outcomes Report to Top Management on the performance of the QMS; on opportunities for improvement; on change requirements; on innovations Ensure the promotion of customer focus Ensure the integrity of the QMS is maintained Roles & Responsibilities • Responsible for the design, development, and documentation of low to medium voltage switchgear and power distribution systems • Ensure compliance with relevant industry standards, customer requirements, and MCM quality standards. Key Responsibilities: • Design and develop electrical switchgear systems including – general requirements, elevation and plan views, one-line diagrams, schematics, and control circuits. • Select and specify electrical components such as breakers, relays, CTs, PTs, bus bars, and protective devices. • Create and revise engineering drawings using CAD software (AutoCAD, E-Plan). • Ensure designs comply with relevant standards (e.g., IEC, ANSI, UL, IEEE). • Collaborate with cross-functional teams including mechanical designers, project managers, and manufacturing teams. • Review and interpret customer specifications and provide technical input during submittal, production, and post-shipment phases. • Maintain project documentation and provide timely updates to project stakeholders. Work Environment: • Self-directed, able to work autonomously or with limited direct supervision, receives general instructions on new assignments. • Typical work week - 40 hrs. • This is an on-site position unless approval is given by management based on a major life change • Willingness to work 10% overtime as needed. • Travel is not required for this position. Qualifications: The successful Design Engineer must: • Demonstrate accuracy, thoroughness, and impeccable attention to detail and organizational skills while successfully managing many concurrent projects • Define problems, collect and interpret data, establish facts, draw valid conclusions, and implement effective solutions in a timely manner • Communicate clearly and effectively • Read and understand contracts, specifications, technical drawings, procedures, and manuals • Approach others in a tactful manner, react well under pressure, treat others with respect and consideration regardless of their status or position, accept responsibility for own action, and follow through on commitments. • Use strong problem-solving, analytical, and communication skills through various stages of each project. Skills/Knowledge/Traits • Positive attitude • Strong work ethic • Time management skills • Good written and verbal communication skills • Problem-solving skills • Works well under pressure • Team player Experience & Education: The well-qualified Design Engineer will have: • A Bachelor of Science degree, preferably in Electrical Engineering, or an Electrical Emphasis of a more General Engineering degree • A technical degree or certificate with a minimum of three years’ relevant experience • 3+ years of experience in switchgear or power distribution equipment design. • Experience with AutoCAD, E-Plan, and Microsoft software • Familiarity with low and medium voltage systems (up to 38kV). • Strong understanding of electrical protection and control systems. • Knowledge of relevant electrical standards (IEC, IEEE, UL, NEMA, etc.). • Hands-on experience in manufacturing or field service of switchgear.
MCM Engineering II has been making custom switchgear for 25 years and is an OEM of Medium Voltage (601 Volts to 38,000 Volts) Switchgear that complies with ANSI C37.20.1, C37.20.2 (Metal Clad) and C37.20.3 (Metal Enclosed). We have the ability to assist you from initial engineering and design to final construction. MCM Engineering II also does Low Voltage (480V) for highly custom applications, including Sheltered Aisle (Walk-in) extensions, wrapping in corrosion resistant material (316SS, 304SS), and integration of alternate products into the Switchgear.
Common Switchgear products are constructed in NEMA 1 (Indoor), N3R Non Walk-In, Sheltered Aisle (Walk-in), and Power Distribution Centers. Types of products manufactured are standard Switchgear lineups (Main and Feeder), Paralleling Switchgear, Marine Skids, Substations, Integrated Power stations, Utility Metering, and severe environment Switchgear.
MCM Engineering II utilizes copper for all bus work and sizes the bus at 1000A per Square Inch for conservative design and heat rise. SCADA and Auto transfer systems are integrated into the product per the customer specifications and industry standards.
Our client base is as varied as the applications: Military, Industrial, WWTP, Commercial, Solar, Geothermal, Wind, Oil and Gas, Mining, Municipalities, and Utilities.
In most instances we offer faster lead times than the major manufacturers and are much more flexible. We offer a wide array of components and configurations to meet your requirements. The pricing is structured to be competitive with the market even on custom fast track shipments and add to existing lineups.
Give us a call or email and we’d be happy to assist in any way possible. 435-865-0125